Structural Concrete, Vol. 3, no. 3, December 2002

19.08.2011   News

Vijay Chandra, Parsons Brinckerhoff Quade and Douglas, Inc.Anthony L. Ricci, Massachusetts Turnpike AuthorityPaul J. Towell, Parsons Brinckerhoff Quade and Douglas, Inc.Keith Donington, Parsons Brinckerhoff Quade and Douglas, Inc.Boston, in the forefront of the American Revolution over two centuries ago, is now in the forefront of another revolution - in the field of cable-stayed bridge technology. A highly complicated structure, unique in the world, is complete. New technologies and innovations have become hallmarks of the Leonard P. Zakim Bunker Hill Bridge. This crossing of the Charles River at the north end of Boston was a challenging assignment from the start. It brought the community, engineers, and architects together to create a 'signature bridge' and a 'gateway' to the city. Located at a pre-eminent point where Paul Revere crossed in 1775, warning colonists that the British were coming, the bridge took on special meaning from a historical perspective. Numerous alternatives were studied for the crossing and the interchange configurations on both sides of the river. Eventually, the option known as the 'non-river tunnel' alternative was chosen, which required a ten-lane crossing of the Charles River. The ten lanes include four lanes each for Interstate 93 (I-93) northbound and southbound, as well as a two-lane ramp on the east side. Some impediments the bridge had to contend with included the Orange Line subway adjacent to and below the bridge; the close proximity of the Charles River lock and dam, and the need to maintain navigation; a major water main in the area of the south tower footing; a cantilevered two-lane ramp on only one side of the structure; the existing Storrow Drive ramps at the south end, dictating the arrangement of the stay cables in the back spans; and a new tunnel at the south end of the structure.

Read more
Structural Concrete, Vol. 3, no. 3, December 2002

19.08.2011   News

Vijay Chandra, Parsons Brinckerhoff Quade and Douglas, Inc.Anthony L. Ricci, Massachusetts Turnpike AuthorityHany Riad, Parsons Brinckerhoff Quade and Douglas, Inc.Jonathan Hren, Parsons Brinckerhoff Quade and Douglas, Inc.Boston's Central Artery/Tunnel project is the largest infrastructure undertaking ever attempted at a single US location. It involves reconstructing Interstate 93 (I-93) by depressing it into a tunnel and subsequently removing the original elevated highway (known as the 'Central Artery'). The new I-93 will emerge from the tunnel near the south bank of the Charles River and rise to cross the river on a cable-stayed bridge. This structure, unique in the world, will be both longitudinally and transversely asymmetrical. The second phase of the project extends the Massachusetts Turnpike (I-90) through South Boston and under Boston Harbour to Logan International Airport. This paper reports on the current status of the project and its many interchanges.

Read more
Structural Concrete, Vol. 3, no. 3, December 2002

19.08.2011   News

Paul J. Towell, Parsons Brinckerhoff Quade and Douglas, Inc.Vijay Chandra, Parsons Brinckerhoff Quade and Douglas, Inc.Peter A. Mainville, Parsons Brinckerhoff Quade and Douglas, Inc.Elie Homsi, Rizzani de EccherThe first part of this series of articles on Boston's Central Artery/Tunnel project presented an overview of the scope of the work and the many interchanges that form the hubs of the project. This second paper describes the innovative use of precast segments, as well as other construction techniques, on two major interchanges.

Read more
Structural Concrete, Vol. 3, no. 3, September 2002

19.08.2011   News

K. S. Elliott, University of NottinghamMixed construction is now being used in the majority of new multi-storey buildings, once the traditional domain of cast-in-situ concrete and structural steelwork. Mixed precast construction means the combined use of precast concrete with steelwork, timber, cast-in-situ concrete and masonry. The combination is made for the benefit of the building process at large and does not necessarily have to be designed and constructed compositely. Mixed construction maximises the structural and architectural advantages in combining components made of different materials, but it requires the cooperation of the architect, structural designer, services engineer, manufacturer, supplier and contractor. It is possible that some client and architectural demands can only be satisfied using mixed construction. In 2002 the fib Commission 6 on Prefabrication will publish a state-of-the-art report on the use of precast concrete in mixed construction. This paper summarises the report.

Read more
Structural Concrete, Vol. 3, no. 3, December 2002

19.08.2011   News

Z. Smerda Technical University Brno, VIAPONT Ltd, Brno, Czech RepublicJ. Smerda VIAPONT Ltd, Brno, Czech RepublicThe rising volume of traffic on concrete road bridges has caused designers to consider the problem of permanent deflections caused by repeated traffic loading. However, it should be stated that the correct method for calculating such deflections is currently unclear and consequently gives rise to unrealistic estimations. Moreover, a lack of knowledge regarding the full spectrum of traffic loads and the effects of repeated loads upon concrete deformation exacerbate the problem. This paper attempts to determine the permanent deflection of prestressed concrete bridges without cracks.

Read more
Structural Concrete, Vol. 3, no. 3, December 2002

19.08.2011   News

Catherine G. Papanicolaou, University of Patras, GreeceThanasis C. Triantafillou, University of Patras, GreeceThis paper presents a minimum cost design procedure for precast structural sandwich panels made of HPC (high-performance concrete - i.e. high-strength and fibre-reinforced) faces and a pumice aggregate concrete (PAC) core, which might also include a layer of thermal insulating material. Attention has been focused on the selection of materials' strength and members' geometrical parameters, as well as on the material cost functions for both concrete types. The strength-based design case study resides with the format of Eurocode 2 and takes into consideration failure modes associated with in-plane loading, such as flexure, shear and local buckling of the compressed faces, with respect to the presence of the insulating layer. The solution of the optimisation problem is attained through the development of a computer program using available algorithm codes provided by Matlab®. The optimisation procedure results in the derivation of design recommendations, which encompass the objective of minimum cost for the elements under investigation.

Read more
Structural Concrete, Vol. 3, no. 3, September 2002

19.08.2011   News

Neil R. Short, Aston University, BirminghamJohn A. Purkiss, Aston University, BirminghamSarah E. Guise, Aston University, BirminghamPetrographic techniques have been developed to determine the nature and density of cracks that have developed after subjecting concrete to steady-state and transient heating regimes. The steady-state investigations showed that there was a good correlation between measurements of crack density and measurements of residual compressive strength. Crack density measurements taken on samples after transient heating have shown that the depth to which the compressive strength of the concrete is likely to have been significantly affected can be identified. Thus, this technique should provide very useful information for the evaluation of fire-damaged concrete.

Read more
Structural Concrete, Vol. 3, no. 3, September 2002

19.08.2011   News

Sérgio M. R. Lopes, University of Coimbra Ricardo N. F. do Carmo, Polytechnic of Coimbra This paper presents an experimental study on the bond of strands prestressed by pretensioning to concrete. Ten beams with different cover values were tested and the results are presented and analysed. In eight of the beams, transfer of the prestressing force was gradual, and sudden in the remaining two beams. A relationship between the transmission length and the bond draw-in at the end of the beam is proposed and compared with predictions found in the literature. The variation of the tendon force along the transmission length is also plotted on graphs and the results are compared with those proposed by Rôs. The comparison with Rôs' predictions shows that experimental values obtained in the current investigation deviate from the expected values by up to 10%.

Read more
Structural Concrete, Vol. 3, no. 2, June 2002

19.08.2011   News

G. De Schutter, Ghent University, Belgium K. Audenaert, Ghent University, Belgium J. De Rouck, Ghent University, Belgium LD-slag is an industrial by-product resulting from the transformation of hot metal into steel by oxygen refining. In order to avoid waste disposal, the incorporation of LD-slag in concrete armour units for breakwaters has been studied. Due to the higher density of LD-slag in comparison with traditional aggregates, a higher hydraulic stability of the armour units is obtained for a given unit size. Static loading tests showed that the mechanical behaviour of breakwater armour units made with the LD-concrete is comparable to the mechanical behaviour of units made with traditional concrete. However, durability problems might occur due to an insufficient volume stability of the LD-slag. To overcome this problem, treated slag has to be used.

Read more